Design and Risk Management for Medical Devices

Engineering and quality specialists reviewing a handheld medical device prototype and design records.

Connect design requirements, risk controls and the evidence behind your device decisions. Elexes supports ISO 14971 risk management for medical devices through focused reviews, documentation development and remediation alongside your engineering and quality teams.

For QA/RA leaders, product teams and medical device founders preparing for a development milestone, design transfer or review, we help identify what is missing and organize the work needed to close the gaps.

When Design Records and Risk Files Stop Telling the Same Story

A change in design gets to testing phase but the risk analysis is for the earlier iteration. The risk control is indicated as “Done” while the test documentation can’t be located. Discrepancies like this create problems during release and review preparation.

Our work connects product-level evidence with your broader QMS Controls & Ongoing Compliance, so responsibilities, approvals and records support the same device configuration.

Engage us when you are:

⦿ Establishing development and risk processes for a new device.

⦿ Preparing design transfer, a submission or an audit.

⦿ Addressing missing traceability or inconsistent legacy records.

⦿ Introducing software, usability or cybersecurity changes that affect safety.

Design and Risk Management Services

Medical Device Design and Development

Structure development plans, inputs, outputs, reviews, verification, validation and transfer records around your product and applicable requirements. Connect user needs to acceptance criteria through Medical Device Design and Development.

Design Documentation and File Remediation

Review existing design records, map missing evidence and prepare a prioritized remediation plan. Our Design History File Remediation support addresses legacy file gaps while keeping original evidence and newly generated records distinguishable.

Medical Device Risk Management

Develop or review risk management plans, hazard analyses, risk evaluations, control traceability and risk management reports. Medical Device Risk Management support includes residual-risk evaluation and production and post-production feedback arrangements.

Software Quality Management

Connect software requirements, development records, testing, unresolved anomalies and change history to device risks. Software Quality Management helps keep software lifecycle evidence consistent with the released configuration.

Medical Device Cybersecurity Quality

Bring security-related requirements, risk controls, verification and maintenance responsibilities into your quality processes. Medical Device Cybersecurity Quality support connects cybersecurity activities with safety risk management where relevant.

Usability Engineering

Link intended users, use environments and safety-related tasks to use-related risk analysis and evaluation evidence. Usability Engineering support helps identify the records and specialist evaluation activities your development program needs.

Clinical Process Quality

Where clinical investigations are part of your program, Clinical Process Quality support addresses relevant procedures, responsibilities and controlled records, with interfaces to clinical and risk documentation agreed in scope.

ISO 14971 Risk Management That Connects to Design Evidence

Clinician evaluating a handheld device in a simulated-use setting while specialists observe and record evidence.

ISO 14971:2019 provides a lifecycle process for hazard identification, risk assessment, implementation of controls, and control effect evaluation. ISO 14971:2019 mandates manufacturers to establish risk acceptability criteria but does not mandate a universally accepted level of risk.

We help translate that process into linked records: the hazard and sequence of events, hazardous situation, potential harm, evaluated risk, selected controls and evidence that those controls were implemented and effective. An FMEA can contribute to the analysis, but it does not by itself cover the full risk management process.

For instance, a control put in place in order to ensure there is no incorrect dosage must relate to a requirement that is well-defined and the way of verifying such a requirement must be made known. The validation part involves determining whether or not the system fulfills the users’ requirements.

In the case of US-market devices, we look at the framework of FDA QMSR in addition to the requirements of your device and the market. ISO 14971 assistance does not substitute for the general requirements of your device.

How the Engagement Works

Share the intended use, device configuration, target markets and available design and risk files. We identify missing links, evidence gaps and decisions requiring your technical team’s input.

Define the workstreams, deliverables, owners, dependencies and review checkpoints. The schedule is agreed after the initial file review, based on record volume, technical complexity and any testing dependencies.

We prepare or update agreed documents and facilitate technical reviews. You provide your product knowledge, testing evidence, and approved sign-off on the agreed scope. The open items are visible until we get the necessary evidence.

What You Receive

Depending on your scope, outputs may include:

⦿ A design and risk documentation gap assessment with priorities and owners.

⦿ Development and risk management plans or procedure updates.

⦿ Hazard analysis, risk evaluation and risk-control records.

⦿ A traceability matrix linking requirements, controls and supporting evidence.

⦿ A verification and validation evidence register with unresolved gaps.

⦿ A risk management report and documented review actions.

⦿ A maintenance plan connecting changes and post-production feedback to file updates.

Founder Perspective

Parul Chansoria, founder of Elexes, with a message connecting design decisions, risk controls and verification evidence.

Support at the Stage You Need It

Go for a single run file review, a documentation project or continuous support depending on pre-agreed development milestones. Technical testing, usability tests and clinical testing are scoped out separately where necessary.

When your records expose wider process gaps, QMS Remediation Services can support the corrective work. After release, connect updates through Change and Lifecycle Quality and Complaint and Post-Market Quality.

Check whether your intended use, risk decisions, design requirements and test evidence remain connected before the next milestone. This one-page checklist includes 18 checks across six areas, with space to record the priority action and owner.

FAQs

Frequently Asked Questions!

The scope can cover your risk management plan, hazard analysis, risk evaluation, control selection, verification links, residual-risk evaluation, report and feedback process. We agree the required records and technical inputs after reviewing your device and existing documentation.

An FMEA is a useful analysis tool, but a complete process also addresses hazards, hazardous situations, harms, risk-acceptability decisions, controls, residual risks and lifecycle feedback. We assess how your existing analyses fit into that wider process rather than treating one worksheet as the entire file.

Sure enough, one can map evidence that exists, find the gap, and make corrections for those specific records. Gap in the historical evidence is identified. Any subsequent analysis or test would be mapped along with its actual date and history of approvals.

Assess changes for their effect on intended use, requirements, hazards, controls and existing evidence. The assessment determines which analyses, tests and approvals need updating. Production experience and complaints can also trigger risk-file review.

Timing depends on the number of devices, maturity of the records, available engineering inputs and whether new testing is needed. We agree milestones and review cadence after the initial assessment. A focused file review and a full development documentation project require different schedules.

Connect Your Design Decisions to Clear Evidence

Share your device stage, target markets and the documentation challenge you need to resolve. We will help define a focused scope, practical outputs and the technical inputs needed from your team.

A Trusted Team of Consultants

Elexes offers a globally recognized ISO 13485 certification consultant who is renowned to enhancing your business credibility in the medical devices industry.

Local Language
Auditor

Our presence across the globe ensures audits are conducted by local-language auditors, facilitating clear communication and understanding.

Why Choose Elexes?

Expertise

Our experts provide guidance and consultants to help you adhere to necessary regulations, ensuring your products meet all legal requirements and is compliant to all necessary standards.

Local Regulatory Certification

At Elexes, we offer to assist in securing additional local certifications, enabling you to manufacture and sell medical devices in various markets across the globe.

Confidentiality

We offer complete confidentiality to all our clients which makes us one of the most trusted regulatory and quality compliance consulting.

Associated Regulatory Authorities.

img
We’ve More
Than 256+ Global Clients
The Best RA & QA Consultants
Clients Testimonials

Amazing Feedback About Our Services

Popular Clients

We’ve 200+ Global Premium Clients

Saneso
Niramai
Apex dental sensors
Neurasignal
SS inovations
Amaryllis
Inclode
iMedisync
DJOGlobal logo cmyk_TM
Summus Laser Logo
Looking For Regulatory Assistance?

Let's Talk How We Can Help You?

Please enable JavaScript in your browser to complete this form.
Name
img
Please enable JavaScript in your browser to complete this form.
Name
img
Please enable JavaScript in your browser to complete this form.
Name
img
Please enable JavaScript in your browser to complete this form.
Name
img
Please enable JavaScript in your browser to complete this form.
Name
img