ISO 13485 Monitoring and Measuring Controls

Can your team explain why an instrument is suitable for the product decision it supports? Elexes helps medical device companies translate ISO 13485 calibration requirements into equipment controls, usable records and defensible acceptance decisions.

Starting from a simple equipment register to site remediation, we help you link measurement requirements with quality management activities through our ISO 13485 consulting services.

What ISO 13485 Requires for Measuring Equipment

Clause 7.6 of ISO 13485:2016 addresses the monitoring and measuring equipment needed to demonstrate product conformity. Organizations must establish controls that support valid results. The applicable equipment depends on your activities, product requirements and responsibility for outsourced work.

While calibration compares an instrument against a reference, verification ensures that the requirements have been met. When calibration and/or verification is required for obtaining accurate readings, equipment should be calibrated, verified, or both periodically or prior to use. Maintenance contributes to keeping equipment in good condition, but doesn’t guarantee accurate measurements.

Applicability is not determined simply by whether you manufacture in-house. Specification developers and legal manufacturers should address measurement activities performed by suppliers where those activities support their product conformity responsibilities.

How Elexes Supports Calibration and Measuring Equipment Control

Equipment Suitability and Status

We help define the measurements your team needs, the instruments appropriate for them, and the procedures governing use. Practical controls include unique identification, required range and accuracy, ownership, location and visible status. Safeguards against inappropriate adjustments, damage and deterioration should extend to handling, maintenance and storage.

A current sticker is useful, but it cannot establish that an instrument is suitable for a particular acceptance limit.

 Software Used for Monitoring and Measurement

Software used to monitor or measure product requirements needs validation for its intended application before initial use and, as appropriate, after changes. The approach should reflect the risk associated with use, including its effect on product conformity. Elexes supports intended-use definitions, risk assessments, validation documentation and change reviews for relevant test software, automated measurement systems and calculation tools. Keep validation results, conclusions and necessary actions. This is distinct from validating software incorporated into the medical device itself.

 Calibration Evidence, Traceability and Intervals

Calibration or verification must use traceable national or international measurement standards where available. If no such standards exist, record the basis used. Retain results and review whether the evidence supports the instrument’s intended use. NIST’s metrological traceability guidance explains why traceability alone does not establish fitness for purpose. Range, results and relevant measurement uncertainty also matter when evaluating a certificate.  The standard does not provide for a single annual period. Base the interval on evidence-based reasoning considering equipment recommendations, usage, environment, measurement significance, and measurement performance experience. Connect outsourced calibration with purchasing and supplier controls.

Failed Checks and Affected Product

If the equipment is not suitable for use, evaluate and document the validity of previous measurement data and take proper action regarding the equipment and the products.

A practical review identifies the potentially affected measurements, product or lots, available historical evidence and justified disposition. Depending on the findings, action could include retesting, product containment or escalation through nonconformity and CAPA controls.

A failed calibration does not automatically determine the same outcome for every product.

Medical device engineering and quality professionals reviewing test equipment and product acceptance records.

ISO 13485 Guidelines Your Team Can Apply

Start with the use of an equipment register according to accepted procedures and acceptance criteria for products. Delegate the control procedure and evidence review to QA, measurement suitability to engineers, and status and pre-use inspection to trained users. External suppliers should be left to purchasing.

Prior to use, check on the status of the instrument. During regular reviews, consider upcoming dates for certification, failure and interval assumptions. After repair, movement or change in software, determine if additional calibration or validation is necessary.

These implementation practices help organize evidence; a particular register template or software platform is not mandated. Align applicable controls with production and service provision, without treating calibration as a substitute for required process validation. Additional market or product requirements should be assessed separately.

From Documentation to Reliable Decisions

The proper operation of the system allows a new member of staff to select the right instrument, verify its status and also find out why the instrument was issued. Warnings include unread certificates, unexplained late instruments, and failed checks not closed after checking for product effects.

Elexes provides the solution for gap analysis, first time through, equipment registration, certificate reviews, measurement software documentation, and remediation. Calibration and test execution in the laboratory require a separate scope definition.

Parul Chansoria, founder of Elexes, on connecting measurement evidence with medical device acceptance.
Check equipment suitability, intervals, traceability, software validation and responses to unreliable measurements. Use the one-page checklist to record gaps, identify supporting evidence and assign follow-up.
FAQs

Frequently Asked Questions!

No. ISO 13485 does not prescribe one universal annual calibration interval. Where calibration or verification is necessary for valid results, establish specified intervals or checks before use. Base intervals on equipment use, measurement criticality, manufacturer recommendations, operating conditions and performance history.

Calibration establishes the relationship between an instrument’s readings and reference values. Verification confirms whether specified requirements are met. Depending on its intended use, equipment may need calibration, verification or both.

Software used to monitor or measure product requirements needs validation for its intended application before initial use and, as appropriate, after changes. The validation approach should reflect the risk associated with its use and its effect on product conformity.

Build controls that your engineering, production, and quality teams can use consistently. Ask Elexes to review your equipment controls and prioritize the gaps affecting product decisions.

A Trusted Team of Consultants

Elexes offers a globally recognized ISO 13485 certification consultant who is renowned to enhancing your business credibility in the medical devices industry.

Local Language
Auditor

Our presence across the globe ensures audits are conducted by local-language auditors, facilitating clear communication and understanding.

Why Choose Elexes?

Expertise

Our experts provide guidance and consultants to help you adhere to necessary regulations, ensuring your products meet all legal requirements and is compliant to all necessary standards.

Local Regulatory Certification

At Elexes, we offer to assist in securing additional local certifications, enabling you to manufacture and sell medical devices in various markets across the globe.

Confidentiality

We offer complete confidentiality to all our clients which makes us one of the most trusted regulatory and quality compliance consulting.

Associated Regulatory Authorities.

img
We’ve More
Than 256+ Global Clients
The Best RA & QA Consultants
Clients Testimonials

Amazing Feedback About Our Services

Popular Clients

We’ve 200+ Global Premium Clients

Saneso
Niramai
Apex dental sensors
Neurasignal
SS inovations
Amaryllis
Inclode
iMedisync
DJOGlobal logo cmyk_TM
Summus Laser Logo
Looking For Regulatory Assistance?

Let's Talk How We Can Help You?

Please enable JavaScript in your browser to complete this form.
Name
img
Please enable JavaScript in your browser to complete this form.
Name
img
Please enable JavaScript in your browser to complete this form.
Name
img
Please enable JavaScript in your browser to complete this form.
Name
img
Please enable JavaScript in your browser to complete this form.
Name
img