Elexes supports IVD manufacturers with IVDR Performance Evaluation Report (PER) preparation, review and remediation, including evidence-gap assessment, literature and evidence review, and technical-documentation alignment.

This service is for manufacturers preparing or updating IVDR performance evaluation documentation when evidence is dispersed, a current PER needs remediation, or the Performance Evaluation Plan, evidence records and technical documentation need a consistency review.

Discuss Your IVDR PER Documentation Needs

What does IVDR PER preparation support cover?

An IVDR Performance Evaluation Report, or PER, documents the evaluation of evidence supporting an IVD’s performance and intended purpose. Under Regulation (EU) 2017/746, Article 56 and Annex XIII, Part A, the performance evaluation addresses three distinct aspects:

  • Scientific validity
  • Analytical performance
  • Clinical performance

PER work begins by defining the IVD, its intended purpose and the evaluation scope. Available evidence can then be assessed for whether it supports that intended purpose.

The report should identify evidence gaps and limitations, and document the rationale for its conclusions. PER preparation, review or remediation does not by itself establish conformity with the IVDR.

For wider context on the applicable framework, see EU IVDR requirements and technical documentation.

How do the Performance Evaluation Plan, evidence and PER fit together?

The Performance Evaluation Plan sets out the intended method and approach for evaluating performance. The PER is different: it records the evaluation of the available evidence and the resulting conclusions. Individual performance studies and their reports are also distinct from the PER.

Under IVDR Annex XIII, the PER brings together the scientific validity report, analytical performance report, and clinical performance report, together with an assessment of the evidence supporting the device’s intended purpose.

Component Evidence focus Documentation consideration
Performance Evaluation Plan Planned approach and methods for evaluating performance Keep the plan distinct from the PER, which records the evaluation and conclusions
Scientific validity Evidence supporting the association between the analyte and a clinical condition or physiological state Explain the evidence supporting the association for the intended purpose
Analytical performance Evidence that the device detects or measures the analyte correctly Assess evidence in relation to the device’s intended purpose and claimed performance
Clinical performance Evidence that results correlate with the relevant clinical condition or physiological or pathological process or state Relate conclusions to the intended purpose, target population and intended user
PER Evaluation of the evidence and resulting performance conclusions Trace conclusions to reviewed evidence and align with technical documentation
PMPF Post-market performance data used to update performance evaluation Document the PMPF process separately and align it with ongoing performance evaluation

The performance evaluation should consider evidence for scientific validity, analytical performance and clinical performance in relation to the specific device and intended purpose. The requirements for the Performance Evaluation Plan and evaluation documentation are set out in Regulation (EU) 2017/746, Annex XIII, Part A.

How does a PER address scientific validity, analytical and clinical performance?

The IVDR distinguishes three performance aspects. Keeping them separate in the PER makes the basis for each conclusion clearer and connects the reviewed evidence to the IVD’s intended purpose.

Scientific validity

Scientific validity concerns the association of an analyte with a clinical condition or physiological state. The PER should describe the evidence supporting that association for the intended purpose.

Analytical performance

Analytical performance concerns the ability of a device to detect or measure an analyte correctly. Relevant evidence should be assessed against the IVD’s intended purpose and claimed performance.

Clinical performance

Clinical performance concerns the ability of a device to yield results that correlate with a particular clinical condition or physiological or pathological process or state, in accordance with the target population and intended user.

The definitions of these terms are set out in Regulation (EU) 2017/746, Article 2. The PER should trace conclusions to the evidence reviewed and explain relevant evidence limitations.

How can Elexes prepare, review or remediate an IVDR PER?

Elexes can support a defined PER preparation, review or remediation scope. The work may include:

  1. Confirming the evaluation scope. Review the device description, intended purpose, current Performance Evaluation Plan and available evidence.
  2. Appraising the evidence set. Assess scientific validity, analytical performance and clinical performance evidence for relevance, completeness and consistency with the IVD and its intended purpose.
  3. Identifying evidence gaps. Document issues in the available evidence, areas requiring follow-up and the rationale for conclusions.
  4. Preparing or revising the PER. Draft, review or remediate the report for the agreed IVD scope, with conclusions traceable to the evidence reviewed.
  5. Checking documentation alignment. Review consistency between the PER, related performance evaluation documentation and the broader technical documentation.

The scope can be tailored to a new report, an existing PER requiring remediation, or a focused evidence-gap and documentation consistency review. Where needed, this work can complement IVD certification support.

What deliverables can manufacturers expect?

Agreed outputs may include:

  • An evidence-gap assessment identifying issues in available evidence and areas requiring follow-up.
  • A literature and evidence review organized around scientific validity, analytical performance and clinical performance.
  • A drafted, reviewed or remediated PER for the agreed IVD scope.
  • Conclusions traceable to the reviewed evidence, including relevant limitations.
  • A consistency review of the PER against related performance evaluation documentation and technical documentation.
Activity Typical input Potential output
Evidence-gap assessment Device scope, intended purpose, Performance Evaluation Plan and available evidence Gap summary and recommendations for follow-up
Literature and evidence review Relevant scientific literature and device performance evidence Evidence review organized by performance aspect
PER preparation or remediation Existing evaluation records and evidence set Drafted, reviewed or remediated PER for the agreed scope
Technical documentation alignment PER and related performance evaluation documentation Consistency review and identified alignment issues

These activities can support documentation readiness. They do not themselves establish IVDR conformity.

How does PMPF relate to the PER?

Post-market performance follow-up, or PMPF, is a continuous process that updates the performance evaluation. It is documented in a PMPF plan and should be distinguished from the initial performance evaluation and the PER.

When planning or reviewing a PER, manufacturers should consider how post-market performance data will inform ongoing evaluation and how PMPF documentation aligns with the performance evaluation records. The IVDR requires manufacturers to keep performance evaluation documentation updated throughout the device lifecycle.

For related lifecycle documentation, see post-market surveillance for IVDs.

How does an engagement for IVDR PER support work?

  1. Confirm the IVD and intended purpose. Establish the device scope, current documentation and whether the need is PER preparation, review or remediation.
  2. Define the evidence-review scope. Agree the evidence and records to be reviewed, including scientific validity, analytical performance and clinical performance materials.
  3. Agree deliverables and alignment checks. Establish expected outputs and how the PER will be checked against related performance evaluation and technical documentation.
  4. Complete the agreed support activities. Perform the evidence-gap assessment, literature and evidence review, PER work and documentation consistency review within the agreed scope.

Discuss IVDR Performance Evaluation Report support

Elexes provides IVDR consulting support for manufacturers requiring PER preparation, review, remediation or technical documentation alignment.

Discuss Your IVDR PER Preparation or Remediation Scope