Elexes reconstructs an organized view of incomplete medical-device Design History File (DHF) records, assesses traceability gaps, and documents remediation without presenting later-created records as contemporaneous evidence.

This support is for medical-device, SaMD, IVD, implant, wearable, and combination-product teams managing fragmented historical design evidence. It is relevant when a quality review, audit, submission-preparation review, acquisition, or lifecycle change brings incomplete records into focus.

Who needs Design History File (DHF) reconstruction and traceability remediation?

DHF reconstruction is a focused exercise for teams that need to understand what design evidence is available, what it supports, and where traceability remains unresolved. The objective is not to recreate missing contemporaneous records or infer that an activity occurred when source evidence is absent.

It may be appropriate when records are distributed across systems, owners, product generations, or revisions, and the organization needs a clear basis for follow-up. Common business contexts include:

  • An internal quality review
  • An audit
  • Submission-preparation review
  • An acquisition
  • A lifecycle change

Where a company already has a broader remediation need, DHF remediation services may be the better fit. This reconstruction and traceability work can form a defined part of that wider effort.

What problem does a DHF reconstruction review solve?

Incomplete design records can make it difficult to determine whether available evidence relates to the correct device, design activity, revision, or risk control. The immediate problem is often not simply a missing document. It is an unclear relationship between the records that remain.

Elexes helps organize the available evidence into a transparent assessment. The review identifies what is present, what is linked, what conflicts, and what needs further assessment. It does not treat a retrospective summary as proof that historical work occurred at a particular time.

For US scope, the assessment should consider the current 21 CFR Part 820, Quality Management System Regulation and confirm applicability to the device and record type before reaching a regulatory conclusion. For EU scope, technical documentation and post-market surveillance documentation should be assessed against the applicable requirements in Regulation (EU) 2017/745, Annex II and Annex III. These US and EU references should not be treated as interchangeable.

What design records should be included in a reconstruction review?

The review scope depends on the device, jurisdiction, available records, and the question being addressed. Elexes can inventory available evidence across the following categories:

  • Design plans, design inputs, and available revisions
  • Design outputs and available revisions
  • Design review records
  • Verification and validation protocols, results, and associated records
  • Risk-management records and related control evidence
  • Design-change records and linked design evidence, where applicable

For each artifact, the review can capture:

  • Source
  • Date
  • Version or revision
  • Owner or origin
  • Relationship to the device or design activity
  • Known limitations

This is a proposed review method, not a claim that every device or jurisdiction requires the same file structure. Teams needing ongoing organization and upkeep of these records can also consider medical-device documentation maintenance.

How is design traceability assessed?

Traceability assessment maps the evidence that is available between design inputs, design outputs, verification, validation, and relevant risk controls. The resulting assessment should identify missing links, conflicts, and evidence requiring follow-up without assuming compliance.

Record categoryEvidence to inventoryTraceability questionPossible gap or follow-up

Design outputsAvailable output records and revisionsCan outputs be related to the relevant inputs?Document unresolved links for assessment

Verification and validationAvailable protocols, results, and associated recordsWhat evidence supports the claimed verification or validation activity?Record missing source evidence or questions for follow-up

Design planning and inputs Available plans, input records, and revisions Can the evidence be associated with the device and relevant design activity? Identify absent, conflicting, or unlinked evidence
Risk management Available risk records and related control evidence Can relevant risk controls be traced to supporting evidence? Flag gaps or inconsistencies without assuming a control was implemented
Design changes Available change records and linked design evidence Can the change and its supporting evidence be identified? Record missing links and proposed follow-up

A gap register can organize the work by recording:

  • The evidence reviewed
  • The unresolved traceability question
  • The risk or impact requiring follow-up
  • The proposed action

A gap register is a remediation tool. It should not be presented as a regulator-mandated form or as proof of compliance.

How should reconstructed documentation be identified?

Original records should remain intact. Later-created summaries, analyses, and remediation records should be clearly distinguished from original contemporaneous evidence.

For newly created remediation documentation, the record can identify its author, creation date, purpose, evidence basis, limitations, and review or approval status as appropriate to the quality system. This supports a transparent account of what was assessed and when the assessment was created.

Record typeHow to identify itWhat it can supportLimitations to document

Original historical recordRetain its existing source and date informationEvidence of the record as maintainedNote missing context, version conflicts, or other known limitations

Gap register or remediation planIdentify the records reviewed and proposed actionsOrganizes unresolved questions and agreed follow-upDo not describe it as a regulator-mandated form or as proof of compliance

Later-created summary or analysis Identify author, creation date, purpose, and evidence basis A transparent retrospective analysis of available evidence Do not represent it as contemporaneous evidence or as proof an activity occurred at the time

For focused support on the underlying design-record structure, see Design History File support for medical devices.

What does Elexes deliver for DHF reconstruction?

Elexes scopes the work around the device, jurisdictions, available evidence, and the questions the team needs to resolve. Potential deliverables include:

  • Available-records inventory
  • Evidence-to-design traceability assessment
  • Gap register
  • Prioritized remediation plan

Deliverables depend on the agreed scope and available records. This work does not promise to establish compliance or recreate missing historical evidence.

How does a DHF reconstruction engagement work?

  1. Define device and jurisdiction scope. Identify the device, relevant records, and jurisdictions that frame the assessment.
  2. Review available evidence. Inventory the records provided and capture their source, date, revision, relationship, and known limitations.
  3. Assess traceability gaps. Map available evidence and identify unresolved links, conflicts, and follow-up questions.
  4. Agree actions and document remediation. Record the assessment, gap register, and agreed remediation actions while distinguishing later-created analyses from historical records.

How does the current FDA QMSR affect legacy design records?

The FDA Quality Management System Regulation (QMSR) became effective on February 2, 2026, incorporating ISO 13485:2016 by reference into 21 CFR Part 820. Although the QMSR no longer uses the term Design History File (DHF) as a specific regulatory record category, applicable design and development documentation requirements remain under ISO 13485:2016.

Manufacturers are not automatically required to recreate historical design records solely because of the QMSR transition. However, existing documentation should be assessed for applicable compliance gaps, with appropriate corrective actions taken where necessary.

Discuss your incomplete design records and traceability gaps

Need help assessing incomplete design records and traceability gaps? Contact Elexes about DHF remediation services or contact Elexes to discuss the available evidence and appropriate scope for remediation support.

Share This: