ISO 15189:2022 specifies quality and competence requirements for medical laboratories. Accreditation is granted by an accreditation body, not ISO, and applies to a defined laboratory scope.

This guide is for medical laboratory leaders and medical-device RA/QA teams assessing laboratories that support device testing or clinical evidence. It explains what ISO 15189 covers, how accreditation differs from a conformity claim, and what to review before relying on a laboratory’s status.

What is ISO 15189?

ISO 15189:2022, Medical laboratories – Requirements for quality and competence is the international standard for quality and competence in medical laboratories. The current edition identified by ISO is ISO 15189:2022.

The standard applies to medical laboratories. It is not a quality-system certification for a medical-device manufacturer. For device companies, its practical relevance is usually in evaluating a laboratory that performs work supporting device testing or clinical evidence.

It is important to distinguish a laboratory’s conformity claim from accreditation:

  • Conformity concerns whether a laboratory states or demonstrates that it meets specified requirements.
  • Accreditation is an independent assessment by an accreditation body against specified requirements and a defined scope.
  • ISO does not accredit laboratories. Accreditation is granted by the relevant accreditation body.

The ILAC Mutual Recognition Arrangement (MRA) provides information on accreditation bodies and recognition arrangements. It does not remove the need to review the particular laboratory, its current accreditation record, and its defined scope.

What does ISO 15189:2022 cover?

ISO 15189 addresses both laboratory management-system processes and technical competence. A short online checklist cannot replace the published standard or an assessment of the laboratory’s operations against the work it is expected to perform.

At a high level, a laboratory review may need to consider processes and evidence related to:

  • Personnel competence, qualifications, training, and assigned responsibilities.
  • Equipment selection, maintenance, calibration, and suitability for intended laboratory activities.
  • Control and retention of laboratory records, including examination results and supporting documentation.
  • Pre-examination, examination, and post-examination processes, including specimen handling, examination procedures, and reporting of results.
  • Quality management activities, including internal audits, management reviews, nonconformity management, and continual improvement.

The intended work should drive the review. A general statement that a laboratory is accredited does not establish that a particular examination, service, project activity, or location is included in the accredited scope.

ISO 15189:2022 at a glance

Topic What to understand
Purpose Requirements for quality and competence in medical laboratories
Who it concerns Medical laboratories and organizations assessing their laboratory processes and competence
Accreditation Granted by an accreditation body, not by ISO. Check the defined accredited scope.
Medical-device relevance Can inform evaluation of laboratories performing relevant work. It does not itself establish acceptance of every result.

How does ISO 15189 accreditation work?

In general, a laboratory applies to an accreditation body. The accreditation body assesses the laboratory against applicable requirements and the scope for which accreditation is requested.

There is no universal accreditation timeline or identical process across jurisdictions. Assessment stages, ongoing accreditation conditions, surveillance arrangements, reassessment practices, and timing depend on the relevant accreditation body’s policies. The ILAC guidance and policy documents can provide useful reference material, but the accreditation body’s current policies govern its process.

Recognition arrangements between accreditation bodies also have limits. They do not mean that every laboratory result is automatically accepted for every regulatory, contractual, customer, or project purpose.

How can you check whether a laboratory is accredited?

A reliable review goes beyond an accreditation logo or a general claim on a laboratory’s website. Review the current accreditation record and compare it with the exact work you plan to commission.

1. Identify the accreditation body.

  • Identify the organization that granted the laboratory’s accreditation.
  • Confirm that the accreditation body is appropriately recognized for the relevant accreditation activities.

2. Locate the laboratory in the accreditation body’s public directory.

  • Search for the laboratory in the accreditation body’s official directory.
  • Confirm the laboratory’s name, accreditation status, and relevant location.

3. Obtain the current accreditation certificate.

  • Obtain the laboratory’s current accreditation certificate and associated scope documentation.
  • Check the certificate’s validity and any listed conditions.

4. Read the certificate and scope together.

  • Review the accredited examinations or services listed in the scope.
  • Check whether the relevant examination or service is included.
  • Check whether the location performing the work is covered.

5. Compare the scope with the project requirements.

  • Define the work, capability, and location required before selecting the laboratory.
  • Identify applicable regulatory, customer, contractual, and project expectations.
  • Confirm that the laboratory’s accredited scope supports the intended work.

6. Resolve uncertainty before commissioning work.

  • If the directory or certificate does not clearly show coverage, seek clarification from the laboratory and, where necessary, the accreditation body.
  • Obtain confirmation that the specific examination, service, and laboratory location are covered by the accreditation.

Medical laboratory accreditation review checklist

Check Evidence to review Why it matters
Accreditation status Accreditation body directory and laboratory certificate Confirms the laboratory’s stated accreditation status
Scope Certificate scope or associated scope documentation Shows whether the specific examination or service is covered
Location Laboratory address or site listed in relevant accreditation records Helps confirm that the work will be performed at a covered location
Validity and conditions Current certificate and accreditation-body directory or policy Supports checking current status and any applicable conditions
Regulatory or contractual fit Project requirements and applicable authority or customer expectations Accreditation does not automatically establish acceptance of every result

When does ISO 15189 matter to medical-device companies?

ISO 15189 accreditation can be one input when selecting and overseeing a medical laboratory that supports device testing or clinical evidence. It should not be treated as a substitute for the device company’s own assessment.

Start by defining the intended work and the laboratory capabilities needed. Then determine whether the candidate laboratory’s documented accredited scope supports that work at the location that will perform it.

A focused laboratory review should consider:

  • The specific testing or evidence-generating work being commissioned.
  • The laboratory capability needed for that work.
  • Applicable regulatory, contractual, customer, and project expectations.

Accreditation alone does not establish regulatory acceptance of every result. It also does not eliminate the need to assess whether the laboratory and its work are suitable for the planned project.

Where laboratory oversight is part of a broader quality-system need, medical-device quality system management support can help place laboratory controls within the wider quality framework.

Need support with ISO 15189 requirements?

Need support with ISO 15189 requirements or laboratory quality processes? Explore Elexes ISO 15189 services.

Share This: